Liitokala Lii500 Features:

1. Four kinds of charge current regulation (300mA / 500mA / 700mA / 1000mA)
2. It can be of different size batteries while charging(18650/20700/21700/26650……/AA/AAA)
3. The charger preclude the use of a separate screen LCD display, voltage (V) Current (mA) Time (h) Capacity (mAh) resistance (mR)
4. Under charge mode, 4 channel work independently, you can select different charging current for charging and Hunching lithium-ion batteries and nickel-metal hydride batteries.
5. FAST TEST mode, 4 channels can quickly detect the battery capacity, regardless of the lithium-ion batteries and nickel-hydrogen batteries, are working independently. Rapid detection of battery capacity process (1 discharge, 2 full) by the two step
6. NOR TEST mode, the battery capacity is normally detected by the three step process (1 first charged, then discharged 2 and 3 refill), the detection process of the battery capacity;
7. CHARGE and FAST TEST / NOR TEST 3 modes can work simultaneously; independent set charge / fast capacity detection / normal capacity detection;
8.  A variety of protection functions: overcharge and over discharge, short circuit, temperature, 0V voltage activation function, (- ΔV & 0ΔV), 1.65V-2.2V can not be charged, intelligent recognition bad battery and reverse-battery detection protection.
9.  With standard 5V / 1000 mA USB output: from 1 to 4 lithium batteries lithium batteries USB output is completed, the product can not be nickel-metal hydride battery with USB output.

 

Description of the keys:
1. The charger has six buttons, mode selection key (MODE), the current selection key (CURREN), and view the data independently selected key (1234), the use of simple and convenient;
2. Hold down the MODE key in any case and held for 3 seconds to change the CHARGE (charge) mode or FAST TEST, NOR TEST (capacity test) mode, then tap again corresponding to the function keys can be changed within 8 seconds, to current, independent, Hunchong, capacity test, the selected function after 8 seconds into the working state, in working condition can tap the (1234) key to view the current (mA) / capacity (mAh) / voltage (V) / time ( h) / resistance (mR) data reference.

 

Description of the mode:
(A) CHARGE (charging mode)
1. When the power is turned charger, the charger all instant full brightness LCD screen, if the battery is not placed in the display Null, if it is a bad battery will also be displayed into the Null;
2. Insert the batteries power charger, the charger in three seconds or so to measure the internal resistance of the battery, after which the system automatically enters charge mode (CHARGE), the charger automatically default charging current is “500mA, in 8 seconds within the current selection by key (CURRENT) select 300mA, 500mA, 700mA, 1000mA current charging system lock current that you select will be charged in eight seconds, if within 8 seconds, did not make the set, then the system automatically defaults to 500mA charging current, current and other functions at this time will not be changed, if necessary change, need to change the mode button press from the election;
3. In the charge mode (CHARGE), within 8 seconds to change any of independent charging or different current selection, as well as different battery Hunchong. make a simple, 8 seconds tap the corresponding button battery 1234, press mode button to change the mode, press the current key to changing the current, independent, capacity detection function, selected after 8 seconds into the working state, attention according to the battery capacity size to select the charge current, if not fast charge, we recommend charging 500mA, this is the safest;
4. charging mode, by tapping the keys you can switch to view the 1234 charge capacity (mAh) / charging time (h) / battery internal resistance (mR) / charging current (mA), voltage (V) 5 kinds of units, the battery is fully charged After the show, (end of charge);
(B) FAST TEST (rapid capacity test mode)
1. When the power is turned back into the battery charger, 8 seconds touch (mode key MODE) Select (FAST TEST rapid capacity test mode), then press (current selection key CURREN) to select the current system 8 seconds after the lock of your choice to work. Quick Reference Table a capacity test procedure is the first battery is discharged, then the battery is fully charged battery in order to detect and record the battery capacity.
Note that this product capacity test mode, the discharge mode is divided into two kinds, when you select the charge current (300mA, 500mA), the system automatically default discharge current of 250mA, when you select the charge current (700mA, 1000mA) , the system automatically default discharge current of 500mA,
(B) NOR TEST (normal capacity detection mode)
1. NOR TEST mode: is the first battery is full, then the battery discharge discharge capacity to detect and record the battery capacity after the battery is fully automated; capacity detection process with reference to Table II
2. When the power is turned back into the battery charger, 8 seconds touch (mode key MODE), NOR TEST mode is selected, in any mode, press mode button for 2 seconds, you can enter NOR TEST mode;
3. After entering the NOR TEST mode, you can select the current key (CURREN) select 300mA, 500mA, 700mA within 8 seconds, or 1000 mA current, the current system is locked after you select in 8 seconds, if in this 8 the second, did not make the set, then the system will automatically lock 500mA current charging (when selected current is the default charging current is automatically selected when the discharge discharge current 250mA), in which within 8 seconds, Select 700mA or 1000mA current charge, will automatically select the discharge current of 500mA discharge.
4. When the battery is full, the system automatically to discharge, the discharge current to system defaults (select the charging current relationship), and record discharge data to detect the battery capacity, when the screen appears, capacity test mode is finished, At this parameter LCD display is the actual capacity of the battery reference value;.
5. capacity test mode is finished, the charger will be selected current parameters again before charging the battery until full.

Warning:
 Before use, please carefully refer to the instructions, pay attention to the recommendation of the rechargeable battery charging current, do not exceed the recommended charging current.

 

Package includes:

LiitoKala Lii-500 1.2V Or 3.7V Battery Charger